3.3 Media Sensor Adjustment
The Media Sensor detects media presence, and top-of-form (except when using continuous
stock). Adjust the Media Sensor as follows:
A. With media loaded and the Printhead Assembly raised for visual access, grasp the Slide
Tab of the Media Sensor.
B. According to your Media Type, use the Slide Tab to position the Sensor Eye Mark as
described in the table below. (Afterward, if necessary, return to the previous section to
complete the setup.)
Media Type Sensor Eye Mark Position
Die-cut Near the middle of the label
Notched Centered over the notch
Reflective Centered over the black mark
Continuous Near the middle of the media
Media
Sensor
Printhead
Assembly
Sensor Eye
Mark
Slide
Tab
Notes: (1) For SENSOR TYPE selection, see Section 4.2.2 (and if using CONTINUOUS
also set LABEL LENGTH).
(2) For SOP adjustments, see Section 4.2.3.